866-685-4443 | Get in Touch Online ...
Complete Combination Temp. Control (50A), Analog Stats, 440-480V
SKU: TC1-2450/3450
Part №: TC1-2450/3450
Weight: 1.00 lb.
Base Price: $469.00
Availability:
Built to Order – Ships
in 2–
3 weeks
from
Tucson, AZ.
Non-returnable.
Maximum load information
Single-phase (2-pole) | Three-phase (3-pole) | |
Max. watts, 440V | 22.0 kW | 38.1 kW |
Max. watts, 460V | 23.0 kW | 39.8 kW |
Max. watts, 480V | 24.0 kW | 41.5 kW |
Features
- Non-indicating (has no readout)
- Mounted in NEMA 12 enclosure
- Magnetic relay for switching heater load
- 10-ft type J FEP-covered thermocouple (longer lengths available)
- Latching safety relay to de-energize control
- Transformer when required
Brief operating guide
- Power button: Activates or deactivates all power in control.
- Reset button: Reactivates circuit after over-temperature switch is tripped, but not until switch has cooled and solution level is raised enough to cover heated portion of heater element.
- Power pilot light: Indicates that power is on.
- Heat pilot light: Indicates that heater is activated.
- Safety pilot light: Indicates over-temperature situation exists; this light will not go out until problem is corrected and reset switch is pushed to reactivate the control.